Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 57
Filter
1.
Braz. dent. sci ; 24(4): 1-11, 2021. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1337554

ABSTRACT

Objective: TThe study evaluated in vitro the changes in roughness, color stability, and bacterial count of a CAD/CAM Resin Nano-Ceramic material surface treated by various scaling procedures. Material and Methods: 70 disks (5mm diameter, 0.5 mm thickness) of Resin Nano-Ceramic (Lava ™Ultimate, 3M, ESPE) material were cemented in standardized cavities prepared in bovine teeth. A custom-made scaling apparatus of a double pan balance was used for different scaling methods, simulating standard clinical conditions. The specimens were assigned to three main groups: no scaling(C), ultrasonic scaling (U), and manual scaling (M). Each group was then divided into three subgroups according to scaling tip material; stainless steel tip (St), plastic tip (P), and titanium tip (Ti). The surface texture was analyzed quantitatively and qualitatively with a tactile profilometer and atomic force microscopy. A spectrophotometer was used for color measurement. Streptococcus mutans were counted in a colony counter. All the data were tabulated and statistically analyzed. Results: Two-way ANOVA was used to study the effect while One-way ANOVA was performed to compare between study groups. The significance level was set at p ≤ 0.05. The ultrasonic titanium tip(UTi) revealed the significant highest mean value of alterations (p < 0.001). The integrity of the material surface was altered in the form of deep scratches on the ultrasonically scaled surfaces and numerous smaller scratches on the hand-scaled surfaces. Conclusion: The plastic instrument would appear to be the instrument of choice during a routine maintenance procedure for Resin Nano-Ceramic materials (AU).


Objetivo: Este estudo avaliou in vitro as alterações na rugosidade, estabilidade de cor e quantidade de bactérias da superfície de uma resina nano-cerâmica produzida em CAD/CAM tratada por diferentes procedimentos de raspagem. Material e Métodos: 70 discos (5 mm diâmetro, 0,5 espessura) de resina nano-cerâmica (Lava ™Ultimate, 3M, ESPE) foram cimentadas em cavidades padronizadas preparadas em dentes bovinos. Um aparato customizado de raspagem com pratos duplos de balança foram usados para os diferentes métodos de raspagem, simulando uma condição clínica padronizada. Os espécimes foram distribuídos em três principais grupos: Sem raspagem (C), raspagem ultrassônica (U) e raspagem manual (M). Cada grupo foi dividido em três subgrupos de acordo com a ponta do material de raspagem; ponta de aço inoxidável (St), ponta plástica (P), ponta de titânio (Ti). A textura da superfície foi analisada qualitativamente e quantitativamente por um perfilômetro tátil e microscopia de força atômica. Um espectrofotometro foi usado para a mensuração da cor. Estreptococos mutans foram contados em um contador de colônias. Todos os dados foram tabulados e analisados estatisticamente. Resultados: Anova dois fatores foi utilizado para estudar os efeitos, enquanto ANOVA um fator foi utilizado para comparar os grupos experimentais. O nível de significância foi estabelecido em p≤ 0,05. A ponta de ultrassom de titânio (UTi) revelou o valor significante mais alto de alterações (p < 0,001). A integridade da superfície d matérias foi alterada na forma ranhuras profundas, nas superfícies raspada por ultrassom e numerosas ranhuras menores nas superfícies raspadas à mão. Conclusão: O instrumento plástico poderia apresentar-se como um instrumento de escolha durante o pocedimento de manutenção routineira para materiais de resina nano-ceramica. (AU)


Subject(s)
Dental Scaling , Resin Cements , Dental Plaque
2.
Braz. dent. sci ; 24(2): 1-10, 2021. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1178369

ABSTRACT

Objective: The aim of this study was to evaluate the effect of four different mouthrinses on the surface roughness of two nanohybrid resin composites. Material and Methods: Fifty samples were prepared for each of the resin composites (2x8 mm) and a profilometer was used to determine the initial surface roughness (Ra) of each sample. Then, they were divided into 5 subgroups (n= 10), and exposed to the following mouthrinses (12h, 37 ºC): containing alcohol and essential oils; alcohol and chlorhexidine; alcohol-free and essential oils; alcohol free and cetil prydinium chlorite; or distilled water (control). The surface roughness of each sample was measured again. Statistical analyses of the data were performed via two-way ANOVA and Bonferroni tests. Results: Overall, statistically significant differences were not found between the resin composites (p> 0.05), but significant differences were found among the mouthrinses (p< 0.05). Interactions between the mouthrinses and the resin composites was statistically significant (p< 0.05). Both of the resin composites had the highest surface roughness after exposure to mouthrinse with alcohol and essential oils (p< 0.05), followed by mouthrinse with alcohol and chlorhexidine. Both alcohol-free mouthrinses caused surface roughness either similar to distilled water (p> 0.05) or lower than distilled water (p< 0.05) on the nanohybrid resin composites used. Conclusion: The mouthrinses affected the surface roughness of the resin composites in different ways. This was dependent on mouthrinse contents and the chemical structure of the resin composites. Alcohol-containing mouthrinses caused the most changes in the surface roughness of both resin composites (AU)


Objetivo: O objetivo deste estudo foi avaliar o efeito de quatro diferentes enxaguatórios bucais sobre a rugosidade superficial de duas resinas compostas nano-híbridas. Material e Métodos: Cinquenta amostras foram preparadas para cada uma das resinas compostas (2x8 mm) e um perfilômetro foi utilizado para determinar a rugosidade superficial inicial (Ra) de cada amostra. Em seguida, foram divididos em 5 subgrupos (n = 10) e expostos aos seguintes enxaguatórios (12h, 37 ºC): contendo álcool e óleos essenciais; álcool e clorexidina; Óleos sem álcool e essenciais; sem álcool e cloreto de cetilpridínio; ou água destilada (controle). A rugosidade da superfície de cada amostra foi medida novamente. As análises estatísticas dos dados foram realizadas por meio de ANOVA de dois fatores e testes de Bonferroni. Resultados: No geral, não foram encontradas diferenças estatisticamente significativas entre as resinas compostas (p> 0,05), mas diferenças significativas foram encontradas entre os enxaguatórios bucais (p <0,05). As interações entre os enxaguatórios bucais e as resinas compostas foram estatisticamente significativas (p <0,05). Ambas as resinas compostas apresentaram maior rugosidade superficial após exposição ao enxaguatório bucal com álcool e óleos essenciais (p <0,05), seguido do enxaguatório com álcool e clorexidina. Ambos os enxaguatórios bucais sem álcool causaram rugosidade superficial semelhante à da água destilada (p> 0,05) ou menor do que a água destilada (p <0,05) nas resinas compostas nano-híbridas usadas. (AU)


Subject(s)
Oils, Volatile , Chlorhexidine , Composite Resins , Mouthwashes
3.
ROBRAC ; 28(85): 45-52, abr./jun. 2019. Ilus, Tab
Article in Portuguese | LILACS | ID: biblio-1049233

ABSTRACT

Objetivo: Avaliar rugosidade superficial (RS), estabilidade de cor (EC) e morfologia de superfície (MS) de um compósito nanoparticulado após diferentes protocolos de acabamento/ polimento com ou sem irrigação. Material e métodos: Cem espécimes foram confeccionados e divididos em 10 grupos (n=10) conforme protocolo de acabamento/polimento: Tira de poliéster; discos abrasivos (DA); DA+espirais (DAE); DA+multi- -laminada+espirais (DAME); espirais (E); e nenhum polimento. Protocolos com DA, DAE, DAME, e E foram realizados a seco e com irrigação. Após acabamento/polimento, os espécimes foram armazenados em água destilada à 37°C. Durante 14 dias, cinco espécimes de cada grupo foram imersos em café por 5min/dia. A EC foi analisada com Espectrofotômetro (CIEL*a*b*) 0, 7 e 14 dias após armazenamento em água ou imersão em café. A RS foi analisada com Rugosímetro (parâmetro Ra) e MS foi analisada com Microscopia Eletrônica de Varredura (MEV). ANOVA, Tukey e Teste T foram realizados para comparações entre os grupos (α=0,05). Resultados: A irrigação promoveu maior EC nos protocolos DAE e E. Os diferentes protocolos promoveram variação de cor semelhante após 14 dias de armazenamento em água. O protocolo E a seco promoveu os maiores valores RS, sendo inferior ao grupo DAME, que promoveu menor rugosidade e foi semelhante aos demais protocolos. Para DAME e E a irrigação foi significativa para diminuir a rugosidade. Na análise por MEV, E com irrigação apresentaram maior lisura superficial. Conclusão: A irrigação durante acabamento/polimento influencia na EC, RS e MS de compósitos. Os protocolos de acabamento/ polimento DAME e E com irrigação foram mais efetivos.


Aim: to evaluate the surface roughness (SR), color stability (CE) and surface morphology (SM) of a nanofilled composite resin exposed to different finishing/ polishing protocols with or without irrigation. Material and methods: One hundred specimens were prepared and divided into 10 groups (n = 10) according to the finishing/polishing protocol: positive control; abrasive discs (AD); AD + spirals (ADS); AD + multi-laminated + spirals (ADMS); spirals (S); and none. Protocols with AD; ADS; ADMS and S were performed to dry or with irrigation. After finishing/ polishing, the samples were stored in distilled water at 37 ° C. For 14 days, five samples of each group were immersed in coffee for 5min/day. The other samples have been stored in water. The CE of the samples was analyzed with Spectrophotometer (CIEL * a * b *) 0, 7 and 14 days after storage in water or coffee. The SR was analyzed with the Rugosimeter and the SM was analyzed with Scanning Electron Microscopy (SEM). ANOVA, Tukey and T-test were performed for comparisons between the groups (α=0,05). Results: Irrigation offered higher EC in the ADS and S groups. The benefits of color variation are after 14 days. The use of dry spirals promoted the highest SR values, being lower in the ADMS group, which promoted less roughness and was similar to the other protocols. For ADMS and S the irrigation was significant to decrease the roughness. Analysis by MEV, spirals with irrigation greater superficial smoothness. Conclusion: Irrigation during finishing/polishing influences the CS, SR and SM of composites. The finishing/polishing protocols with ADMS and S with irrigation were more effective.

4.
Dent. press endod ; 9(1): 37-42, jan.-mar. 2019. tab, Ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1007600

ABSTRACT

Objetivo: avaliar a resistência máxima à flexão (MFS), módulo de elasticidade (E), microdureza Knoop (KHN) e rugosidade de superfície (Ra) da dentina radicular tratada com solução de clorexidina a 2% (CHX). Métodos: foram selecionados 50 incisivos bovinos com ápice fechado, e trinta raízes foram cortadas em barras de dentina (DB) e divididas em três grupos (n = 10): Controle (sem tratamento), G1 (NaOCl 2,5% + EDTA 17%) e G2 (CHX 2% + H2O). As DB foram submetidas ao ensaio de resistência flexural de três pontos, para se obter os valores de MFS e E. Vinte raízes foram cortadas longitudinalmente ao meio e inseridas em resina acrílica; as superfícies pulpares foram lixadas e polidas e, em seguida, irrigadas de acordo com o grupo (G1 ou G2; n = 20 metades por grupo) e submetidas aos testes de KHN e Ra. Foi realizada análise de MEV. Os dados foram analisados por meio dos testes de ANOVA de um e dois critérios, seguidos do teste de Tukey (α = 0,05). Resultados: os valores de MFS (p < 0,05) e E (p < 0,01) foram maiores para G2. A KHN foi reduzida após o tratamento com cada irrigante endodôntico (p < 0,001), sem diferenças entre eles (p = 0,115). A Ra foi maior para o G1 (p < 0,001). Conclusões: a solução de clorexidina a 2% melhora as propriedades mecânicas de MFS, E e Ra da dentina radicular. (AU)


Objective: To evaluate the maximum flexural strength (MFS), elastic modulus (E), Knoop microhardness (KHN), and surface roughness (Ra) of root dentin treated with 2% chlorhexidine (CHX) solution. Materials and methods: Fifty bovine incisors with closed apex were selected. Thirty roots were cut into dentin bars (DB) and divided into three groups (n=10): control (no treatment), G1 (2.5% NaOCl + 17% EDTA) and G2 (2% CHX + H2O). The DB were submitted to the three-point flexural strength test to obtain the MFS and E. Twenty roots were cut longitudinally into two half-halves and placed in acrylic resin. The pulp surfaces were sanded and polished. They were rinsed according to the group (G1 or G2; n = 20 per group) and subjected to the KHN and Ra tests. SEM analysis was made. Data were analysed by one- and two-way ANOVA and Tukey post hoc test (a = 0.05). Results: The values of MFS (P < 0.05) and E (P < 0.01) were higher for G2. The KHN reduced after both endodontic irrigation treatments (P < 0.001), with no differences between them (P = 0.115). Ra was higher for G1 (P < 0.001). Conclusions: 2% CHX improved the mechanical properties of MFS, E and Ra of root dentin (AU).


Subject(s)
Chlorhexidine , Dental Pulp Cavity , Dentin , Sodium Hypochlorite
5.
Hig. aliment ; 33(288/289): 2390-2395, abr.-maio 2019. tab, ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1482226

ABSTRACT

Superfícies de aço inoxidável com especificações determinadas pela American Society for Testing and Materials (ASTM) são usadas em testes in vitro para simular a formação e a remoção de biofilmes. Muitas vezes estas superfícies são reutilizadas nos ensaios de formação de biofilmes. O objetivo deste trabalho foi avaliar se cupons de aço inoxidável anteriormente utilizados para formação de biofilmes multiespécies podem ser reutilizados em novos ensaios. Assim, cupons submetidos a diferentes procedimentos de higienização foram analisados por microscopia eletrônica de varredura (MEV) e perfilometria . A reutilização das superfícies em novos experimentos deve ser realizada com cautela, aplicando procedimentos que removam as células bacterianas e a substância polimérica extracelular (EPS) aderidas na superfície. Além disso, observações da superfície (topografia e rugosidade) devem ser avaliadas, comprovando as especificações da ASTM.


Subject(s)
Stainless Steel/analysis , Biofilms , Microscopy, Electron, Scanning/methods , Recycling
6.
J. Health Biol. Sci. (Online) ; 7(2): 197-203, abr.-jun. 2019.
Article in Portuguese | LILACS | ID: biblio-1005758

ABSTRACT

Introdução: o acabamento e o polimento das resinas compostas (RC) podem interferir diretamente na rugosidade desses materiais, estando relacionadas com a adesividade de placa bacteriana, manchamento, brilho e lisura. Objetivo: comparar a rugosidade superficial de duas RC, sendo uma micro-híbrida (Filtek Z250) e outra nanoparticulada (Filtek Z350), após a realização dos procedimentos de acabamento e polimento. Métodos: utilizando-se uma matriz metálica, confeccionaram-se quinze discos de cada RC. A lisura superficial proporcionada pela fita de poliéster foi avaliada por meio de um rugosímetro (Hommel Tech-T1000), obtendo-se dados iniciais. Realizou-se a mensuração em triplicata, obtendo-se o valor da rugosidade média (Ra). Lixaram-se as superfícies de topo dos espécimes e seguiu-se nova obtenção da Ra. Os espécimes foram, aleatoriamente, distribuídos em três grupos: GI ­ discos de óxido de alumínio; GII ­ pontas siliconadas e GIII ­ discos de diamante micronizado, sendo obtida a Ra final. Os dados foram analisados pelo teste de Kruskal-Wallis e Qui-quadrado (α=1%). Resultados: a média e o desvio-padrão expresso em µm foram: Z-250 GI - 0,16 (0,09), GII - 0,32 (0,06) e GIII - 0,06 (0,02) e para Z-350 GI - 0,06 (0,01), GII - 0,49 (0,14) e GIII - 0,07 (0,01). Para Z-250, o GIII apresentou melhor polimento, sendo, estatisticamente, diferente de GI e GII (p≤0,01). Para Z-350, não houve diferença estatística entre os GI e GIII, mas eles foram superiores ao GII (p≤0,01). Conclusão: o disco de diamante micronizado proporcionou melhores valores de lisura superficial independente do tipo de resina composta empregada.


Introduction: finishing and polishing of composite resins (CR) can directly interfere with the roughness of these materials, being related to bacterial plaque adhesion, staining, gloss and smoothness. Objective: to compare the surface roughness of two CR, a micro-hybrid (Filtek Z250) and a nanoparticulate (Filtek Z350) after finishing and polishing. Methods: using a metal matrix, fifteen disks of each CR were made. The surface smoothness provided by the polyester tape was evaluated by a rugosimeter (Hommel Tech-T1000) obtaining initial data. Measurements were made in triplicate, and the mean roughness value (Ra) was obtained. The top surfaces of the specimens were sieved and re-obtained the Ra. The specimens were randomly distributed into three groups: GI - aluminum oxide discs; GII - silicone tips and GIII - micronized diamond discs, obtaining the final Ra. Data were analyzed by the Kruskal-Wallis test and chi-square test (α = 1%). Results: the mean and standard deviation expressed in µm were: Z-250 GI - 0.16 (0.09), GII - 0.32 (0.06) and GIII - 0.06 (0.02) and for Z -350 GI - 0.06 (0.01), GII - 0.49 (0.14) and GIII - 0.07 (0.01). For Z-250, the GIII presented better polishing, being statistically different from GI and GII (p≤0.01). For Z-350, there was no statistical difference between GI and GIII, but these were higher than GII (p≤0.01). Conclusion: the micronized diamond disk provided better surface smoothness values independent on the type of composite resin used.


Subject(s)
Composite Resins , Dental Materials
7.
Braz. dent. sci ; 22(3): 305-312, 2019. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1008364

ABSTRACT

Objective: The aim of the study was to evaluate the influence of different surface post-etching treatments in flexural strength, contact angle and surface roughness of a lithium disilicate ceramic. Material and Methods: 60 bars (16 x 2 x 4 mm) were divided in six groups (n=10): C, no treatment; HF, hydrofluoric acid for 20 s (HF) + washing (60 s), drying (30s); HFL, HF + washing (60 s), drying (30 s) and luting; HFNL, HF + washing (60 s) + neutralization with sodium bicarbonate (SB) for 40 s + washing (5s), drying (30 s) and luting; HFUL, HF + washing (60 s) + ultrasonic bath (UB) for 4 min, drying (30 s) and luting; HFNUL, HF + washing (60 s) + SB (40 s) + UB (4 min) and luting. The bars were submitted to three-points flexural strength test. 25 ceramic blocks (12 x 7 x 7 mm) were divided into five groups (n=5) to evaluate roughness and contact angle C - no treatment; HF - HF ; HFU - HF and UB for 5 min ; HFN - HF and SB; HFNU - HF, UB and SB. A scanning electron microscope (SEM) showed the surface of the samples. ANOVA one-way statistical analysis was done for comparison of results. Results: There was no statistical difference for flexural strength (p-value = 0.15) and for surface roughness (p-valor = 0.15). However, it was obtained statistically significant difference for contact angle (p-valor = 0.00). SEM images showed precipitates after the acid etching, which were removed by post-etching treatments. Conclusion: It can be concluded that the different post-etching surface treatments did not increase the flexural strength, surface roughness, but it influenced the ceramic wetting and SEM images (AU)


Objetivo: O objetivo do estudo foi avaliar a influência de diferentes tratamentos pós-condicionamento na resistência à flexão, ângulo de contato e rugosidade superficial de uma cerâmica de dissilicato de lítio. Material e Métodos: 60 barras (16 x 2 x 4 mm) foram divididas em seis grupos (n = 10): C, sem tratamento; HF, ácido fluorídrico durante 20 s (HF) + lavagem (60 s), secagem (30 s); HFL, lavagem com HF + (60 s), secagem (30 s) e cimentação; HFNL, HF + lavagem (60 s) + neutralização com bicarbonato de sódio (SB) por 40 s + lavagem (5s), secagem (30 s) e cimentação; HFUL, HF + lavagem (60 s) + banho ultrassônico (UB) por 4 min, secagem (30 s) e cimentação; HFNUL, HF + lavagem (60 s) + SB (40 s) + UB (4 min) e cimentação. As barras foram submetidas ao teste de resistência à flexão de três pontos. 25 blocos cerâmicos (12 x 7 x 7 mm) foram divididos em cinco grupos (n = 5) para avaliação da rugosidade superficial e ângulo de contato C - sem tratamento; HF - HF; HFU - HF e UB por 5 min; HFN - HF e SB; HFNU - HF, UB e SB. Um microscópio eletrônico de varredura (MEV) foi utilizado para análise da superfície das amostras. A análise estatística unidirecional ANOVA-um fator foi realizada para comparação dos resultados. Resultados: Não houve diferença estatística para a resistência à flexão (p-valor = 0,15) e para a rugosidade superficial (p-valor = 0,15). No entanto, obteve-se diferença estatisticamente significante para o ângulo de contato (p-valor = 0,00). Imagens de microscopia eletrônica de varredura mostraram a formação de precipitados após o ataque ácido, que foram removidos pelos tratamentos pós-condicionamento. Conclusão: Pode-se concluir que os diferentes tratamentos de superfície pós-condicionamento não aumentaram a resistência à flexão, rugosidade da superfície, mas influenciaram na molhabilidade da cerâmica e nas imagens em MEV.(AU)


Subject(s)
Electron Microscope Tomography , Flexural Strength , Hydrofluoric Acid
8.
Braz. dent. sci ; 22(3): 378-386, 2019. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1009381

ABSTRACT

Objective: The objective of this study was to evaluate the alteration of the optical properties of bulk fill resin-based composites after two years of simulated toothbrushing. Material and Methods: Three high-viscosity bulk fill resin composites and one conventional sculptable resin composite (control) were analyzed. Five specimens of each resin composite were prepared, and roughness, color, translucency and gloss were evaluated initially and after one and two years of simulated toothbrushing. The specimens were submitted to electric simulated toothbrushing (14600 strokes / 100 g) using a commercially available soft bristle toothbrush and toothpaste slurry in a proportion of 1:2 by weight. The brushing scheme was of 40 cycles per day (2 cycles per second / 280 cycles in a week). The optical properties and the roughness data were analyzed by a multifactor analysis of variance (MANOVA) and a Tukey post hoc test. Results: The baseline and final values of Ra and Sa were submitted to linear regression analyses, all of which were performed at a significance level of 5%. Gloss and roughness presented statistical differences between the resin-time interactions in all composite resins. The gloss (72.5%) and roughness (89.4%) worsened significantly after brushing, but the authors didn't find statistically significant differences when evaluating translucency and color. Conclusion: Based in the results, it could be concluded that the simulated brushing degraded the gloss and roughness of the used high-viscosity bulk fill composites. (AU)


Objetivo: O objetivo deste estudo foi avaliar a alteração das propriedades ópticas de resinas compostas do tipo bulk fill após dois anos de escovação simulada. Material e Métodos: Foram analisadas três resinas compostas do tipo bulk fill de alta viscosidade e uma resina composta convencional (controle). Cinco corpos-deprova de cada resina composta foram preparados e a rugosidade, cor, translucidez e brilho foram avaliados inicialmente e após um e dois anos de escovação simulada. Os espécimes foram submetidos a escovação dental simulada (14.600 golpes / 100 g) utilizando-se escova de dentes de cerdas macias comercialmente disponíveis e uma pasta composta de dentifrício e água na proporção de 1:2 em peso. O esquema de escovação foi de 40 ciclos por dia (2 ciclos por segundo / 280 ciclos por semana). As propriedades ópticas e os dados de rugosidade foram analisados por uma análise de variância multifatorial (MANOVA) e um teste post hoc de Tukey. Resultados: Os valores iniciais e finais de Ra e Sa foram submetidos a análises de regressão linear, todas realizadas ao nível de significância de 5%. O brilho e a rugosidade apresentaram diferenças estatísticas entre as interações resina-tempo em todas as resinas compostas. O brilho (72,5%) e a rugosidade (89,4%) pioraram significativamente após a escovação, mas os autores não encontraram diferenças estatisticamente significativas ao avaliar a translucidez e a cor. Conclusão: Com base nos resultados, pôde-se concluir que a escovação simulada degradou o brilho e a rugosidade das resinas compostas do tipo bulk fill avaliadas. (AU)


Subject(s)
Toothbrushing , Analysis of Variance , Composite Resins
9.
Braz. dent. sci ; 21(3): 335-340, 2018. ilus, tab
Article in English | LILACS, BBO | ID: biblio-911640

ABSTRACT

Objective: The purpose of this study was to comparatively evaluate quantitative effects of three different prophylactic methods of surface polishing treatments for primary teeth compared to a standardized control group. Material and Methods: 48 naturally exfoliated primary teeth were selected and randomly assigned into four groups: Control Group ­ teeth receiving only enamel standardization treatment with polishing disc to reduce natural enamel; Group I ­ teeth receiving superficial enamel standardization treatment followed by polishing with a mixture of water and pumice; Group II ­ teeth receiving enamel standardization treatment followed by prophylaxis with paste (Herjos-F, Vigodent S/A Indústria e Comércio, Rio de Janeiro, Brazil); and Group III ­ teeth receiving enamel standardization treatment followed by sodium bicarbonate spray (Profi II Ceramic, Dabi Atlante Indústrias Médico-Odontológicas Ltda, Ribeirão Preto, Brazil). All the procedures were performed by the same operator and the samples were rinsed and stored in distilled water. Comparative assessment of the enamel surface roughness between experimental groups and control group was performed by using a surface profilometer (Mitutoyo SJ400). Results: The results of this study were statistically analysed by using Minitab statistical software (version 17.1.0, 2013). The use of pumice and water led to significantly rougher surfaces than in other groups (i.e. Group I: 1.22 Ra; Group II 0.38 Ra; Group III: 1.01 Ra). Conclusion: Based on this study, one can conclude that use of pumice and water resulted in increased enamel surface roughness in comparison to the surface treatment with bicarbonate spray and prophylaxis paste. (AU)


Objetivos: O objetivo deste estudo foi quantificar e comparar a rugosidade do esmalte dentário após de três diferentes tratamentos profiláticos para polimento de superfície de esmalte em dentes decíduos, em relação a um grupo controle. Material e Métodos: 48 dentes decíduos naturalmente esfoliados foram selecionados e alocados aleatoriamente em quatro grupos. Grupo Controle: recebeu apenas padronização do esmalte através do disco de polimento para redução de dentes naturais. O grupo I recebeu padronização superficial do esmalte seguido de polimento por mistura de água e pedra-pomes; o grupo II recebeu padronização do esmalte seguido da pasta de profilaxia Herjos-F (Vigodent S / A Indústria e Comércio, Rio de Janeiro, Brasil); e o grupo III recebeu padronização da superfície do esmalte seguido de spray de bicarbonato de sódio Profi II Ceramic (Dabi Atlante Indústrias Médico Odontológicas Ltda., Ribeirão Preto, Brasil). Todos os tratamentos de superfície foram realizados pelo mesmo operador, por dez segundos e as amostras foram lavadas e armazenadas em água destilada. A avaliação comparativa da rugosidade superficial do esmalte entre os grupos experimentais e controle foi realizada utilizando-se um perfilômetro de superfície Mitutoyo SJ400. Resultados: Os resultados deste estudo foram analisados estatisticamente com o software estatístico Minitab (versão 17.1.0, 2013). A pedra-pomes e a água geraram significativamente maior aspereza na superfície de esmalte, em comparação aos outros grupos, quando empregado o teste estatístico de Tukey (Grupo I: 1,22 Ra; Grupo II: 0,38 Ra; Grupo III: 1,01 Ra). Conclusão: Com base neste estudo, pode-se concluir que a pedra-pomes e a água resultaram em aumento da rugosidade superficial do esmalte em comparação ao tratamento superficial com spray de bicarbonato e pasta profilática.(AU)


Subject(s)
Dental Enamel/abnormalities , Dental Prophylaxis , Tooth, Deciduous
10.
Braz. dent. sci ; 20(4): 124-129, 2017. ilus, graf
Article in English | LILACS, BBO | ID: biblio-878134

ABSTRACT

Objectives: The aim of this study was to evaluate a Y-TZP ceramic sintered by a microwave protocol on volume shrinkage and surface roughness. Material and Methods: Twenty four (N=24) Y-TZP discs were fabricated by milling in CAD/ CAM for size standardization. The mean final dimensions of the specimens were 15 mm X 1.6 mm. Samples were divided into 2 groups (n=12): conventional resistive heating sintering protocol (C - Control) and microwave sintering protocol (MO - experimental). For the characterization of the specimens, surface roughness (Ra and Rz parameters) was evaluated with a roughness tester, and volume shrinkage was measured with a hand micrometer. Data were statistically evaluated by Student's t and Mann-Whitney U tests (α=0.05). Results: The roughness results were: 0.25 µm ± 0.02 (Ra) and 2.68 µm ± 0.666 (Rz) for the MO samples; 0.26 µm ± 0.04 (Ra) and 2.73 µm ± 0.461 (Rz) for the C group (Ra: p = 0.19; Rz: p = 0.81). The shrinkage results was: MO (21.02% ± 2.70) and C (20.10% ± 0.52) (p = 0.274). Conclusion: The conventional and microwave sintering methods were similar regarding surface roughness and volume shrinkage of Y-TZP dental ceramic (AU)


Objetivo: avaliar uma cerâmica de zircônia estabilizada com óxido de ítrio (Y-TZP) sinterizada por um protocolo em micro-ondas quanto à contração volumétrica e a rugosidade superficial. Material e Métodos: Vinte e quatro discos (n = 24) de Y-TZP foram fresados em CAD / CAM para padronização do tamanho. A dimensões finais médias dos corpos de prova foram de 15 mm X 1,6 mm. As amostras foram divididas em 2 grupos (n = 12): protocolo de sinterização convencional por aquecimento resistivo (C - Controle) e protocolo de sinterização por microondas (MO - experimental). A caracterização das amostras foi realizada pela avaliação da rugosidade superficial, com um rugosímetro (parâmetros Ra e Rz) e da contração volumétrica, medida com um micrômetro manual. Os dados foram estatisticamente avaliados pelos testes de t-Studant e U-Mann-Whitney (α=0,05). Resultados: Os resultados de rugosidade foram: 0,25 µm ± 0,02 (Ra) e 2,68 µm ± 0,666 (Rz) para o MO; e 0,26 µm ± 0,04 (Ra) e 2,73 µm ± 0,461 (Rz) para o grupo C (Ra: p = 0,19; Rz: p = 0,81). A contração volumétrica foi de: MO (21,02% ± 2,70) e C (20,10% ± 0,52) (p = 0,274). Conclusão: os métodos de sinterização convencionais e de microondas são semelhantes, no que diz respeito à rugosidade superficial e retração de volume da cerâmica dental Y-TZP. (AU)


Subject(s)
Ceramics
11.
ImplantNewsPerio ; 1(8): 1501-1507, nov.-dez. 2016. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-848533

ABSTRACT

Objetivo: o presente estudo avaliou in situ a adesão bacteriana em função da rugosidade superficial das superfícies de titânio. Material e métodos: 24 discos de titânio (titânio grau 4; 4 mm de diâmetro x 3 mm de altura) foram divididos em quatro grupos: A) controle (liso/sem polimento); B) lixa 320; C) lixa 600; e D) lixa 1.200. Após tratamento, os discos foram fixados na região palatina de aparelhos ortodônticos, utilizados por três voluntários durante quatro horas para formação de biofilme. A adesão bacteriana foi avaliada quantitativamente por meio de imagens obtidas em microscopia eletrônica de varredura. Resultado: a rugosidade superficial foi alterada pelos tratamentos com as lixas, variando entre 0,084 µm e 0,324 µm (p < 0,05). A adesão bacteriana foi significativamente maior no grupo B (p=0,0082), apresentando uma área do titânio recoberta com biofilme de 67,68 pixels/µm2, enquanto o grupo A apresentou uma adesão 3,7 x menor. Conclusão: o aumento da rugosidade superficial aumentou significativamente a adesão bacteriana do biofilme dental in situ, após quatro horas. Futuros estudos são necessários para avaliar a maturação e futura colonização bacteriana por outras espécies que sucedem a colonização inicial.


Objective: the present study evaluated, in situ, the bacterial adhesion based on the titanium roughness surface. Material and methods: 24 titanium disks (titanium grade IV, 4 mm diameter and 3 mm high) were divided in 4 groups: A) control (smooth/without treatment); B) 320 grit sandpaper; C) 600 grit sandpaper, and D) 1.200 grit sandpaper. After treatment, all the disks were fixed at palatal area of orthodontic appliances on 3 volunteers during 4 hours after biofilm formation. The bacterial adhesion was quantitatively evaluated during the first hours using scanning electron microscopy images. Results: the superficial roughness was altered by the sandpaper treatment between 0.084 and 0.324 µm (p < 0.05). The bacterial adhesion was statistically higher for the group B (p=0.0082), depicting titanium area cover by biofilm of 67.68 pixels/µm2, while in group A the adhesion was a 3-fold lower. Conclusion: the superficial roughness increases significantly in situ bacterial adhesion four hours later. Further studies are need to evaluate the maturation and future succession bacterial colonization by other species in the succession after the early events.


Subject(s)
Humans , Male , Female , Adult , Bacterial Adhesion , Dental Implants , Microscopy, Electron, Scanning , Evaluation Studies as Topic , Titanium/analysis
12.
Eng. sanit. ambient ; 21(2): 347-355, tab, graf
Article in Portuguese | LILACS | ID: lil-787451

ABSTRACT

RESUMO: O presente trabalho teve por objetivos determinar a rugosidade relativa dos tubos de PVC e avaliar a sua influência no dimensionamento das redes de distribuição de água, segundo as exigências das NBR 5647-1:2004 e 5647-3:1999. As avaliações foram realizadas para três amostras de tubulações novas de DN 50, 75 e 100 e testemunhos em duplicata de DN 50 e 75, extraídos de campo após 10 e 34 anos de uso, respectivamente. Nas tubulações novas, a rugosidade relativa variou de 5,416 E-05±0,834 E-5 a 6,125 E-4±0,756 E-4. Já para as usadas, ela se alterou de 4,853 E-04±3,221 E-4 a 1,056 E-03±0,419 E-3. Essas rugosidades relativas não influenciaram a determinação do fator de atrito quando calculado pela fórmula de Swamee-Jain.


ABSTRACT: This study aimed at determining the relative roughness of PVC pipes and evaluating its influence on dimensioning the water distribution networks, according to the requirements of the Brazilian regulations NBR 5647-1:2004 and 5647-3:1999. The evaluations were conducted for three samples of new pipes of DN 50, 75 and 100, besides double testimonies of DN 50 and 75, which were taken from the field after 10 and 34 years of use, respectively. In the new pipes, the relative roughness ranged from 5.416 E-05±0.834 E-5 to 6.125 E-4±0.756 E-4. The used pipes ranged from 4.853 E-04±3.221 E-4 to 1.056 E-03±0.419 E-3. These amounts of relative roughness did not influence the friction factor determination when calculated through Swamee-Jain equation.

13.
Bauru; s.n; 2016. 128 p. tab, ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-881295

ABSTRACT

Este estudo in vitro propôs analisar os padrões de condicionamento da superfície da cerâmica a base de dissilicato de lítio após três tempos de condicionamento com ácido fluorídrico a 10%, a influência desses tempos na resistência ao cisalhamento de cilindros cerâmicos e à compressão de placas cerâmicas cimentadas em esmalte de dentes bovinos. Para análise de superfície foram utilizadas 36 placas de cerâmica (IPS e.max Press), sem tratamento e condicionadas por 10s, 20s e 60s (E0,E10,E20,E60; n=3), observadas em MEV, energia dispersiva espectroscópica (EDS) e perfilômetro. Para o teste de resistência de união, 180 cilindros cerâmicos (2mm diâmetro x 2mm comprimento; n=20) foram condicionados e cimentados (80 m de espessura) com RelyX ARC em esmalte variando os sistemas adesivos {Silano+Single Bond (S); RelyX Ceramic Primer Silano +Single Bond (R); Single Bond Universal (U)}, obtendo-se os grupos: E10S, E20S, E60S, E10R, E20R, E60R, E10U, E20U e E60U. Após 24h realizou-se o teste de cisalhamento (EMIC, 0,5mm/min, 50Kgf). O teste de compressão ao esmalte (Kratos, 0,5mm/min 50Kgf) foi realizado após 24h da cimentação de 60 placas cerâmicas quadradas (5x5mm com 1mm de espessura; n=10), condicionadas e cimentadas (RelyX ARC, 80m) variando os sistemas adesivos R e U (10R, 20R, 60R, 10U, 20U e 60U). Os resultados da análise em MEV mostraram que foi mantido o mesmo padrão de condicionamento, porém, mais evidenciado com o aumento do tempo de tratamento. A quantidade de sílicio observada em EDS foi: E0:24,73% < E10:61,10% < E20:67,50% = E60:67,54% e a rugosidade: E0: 6,25 m < E10: 10,6m < E20: 12,0m < E60: 18,0m. Para os resultados dos ensaios de cisalhamento foi usado um modelo linear generalizado, com distribuição normal para a variável resposta e função de ligação do tipo raiz quadrada. Para compressão, usamos um modelo linear normal. Em ambos os casos, a hipótese de normalidade dos desvios foi verificada a partir do Q-Q Plot e do Teste de Kolmogorov-Smirnov. Para os testes de cisalhamento (MPa), independente do tempo de condicionamento, o grupo S apresentou os menores valores, enquanto os grupos R e U apresentaram valores semelhantes (E10S:84,2±7,2A/a, E10R:124,4±7,9A/b, E10U:117,2±7,8A/b, E20S:102,3±7,6B/a, E20R:146,2±8,2B/b, E20U:138,4±7,9B/b, E60S:107,2±7,8B/a, E60R:152,1±8,1B/b, E60U:144,1±8,1B/b). Para o teste de compressão (N), os valores Médios foram: 10R:869,8±122a, 10U:879,3±159a, 20R:795,0±219ab, 20U:852,3±227ab, 60R:772,7±162b, 60U:704,0±235b. O aumento do tempo de condicionamento da superfície da cerâmica a base de dissilicato de lítio aumentou a rugosidade superficial, não demonstrou diferença significativa da resistência de união de 20s par 60s, e apresentou leve diminuição para resistência de compressão.(AU)


The present in vitro study aimed to analyze the etching patterns of lithium disilicate based ceramic after three etching times with 10% hydrofluoric acid, and the influence of these times on the shear bond strength of ceramic cylinders and compression resistance of ceramic plates cemented to bovine enamel teeth. For the surface analysis, 36 ceramic plates (IPS e.max Press) were used untreated and etched for 10s, 20s and 60s (E0, E10, E20, E60; n = 3), as observed in SEM, energy dispersive spectroscopy (EDS) and profilometry. For the bond strength test, 180 ceramic cylinders (2x2mm; n = 20) were etched and cemented with RelyX ARC (80 m thick) on the enamel varying adhesive systems {Silane + Single Bond (S); RelyX Ceramic Primer Silane + Single Bond (R); Single Bond Universal (U)}, yielding the groups: E10S, E20S, E60S, E10R, E20R, E60R, E10U, E20U and E60U. After 24h, the shear bond strength test was performed (EMIC, 0.5 mm/min, 50Kgf). The ceramic compression test (Kratos, 0.5 mm/min, 50Kgf) was performed 24h after etching and cementing (RelyX ARC, 80m) 60 square ceramic plates (5x5mm, 1mm thick; n = 10), varying R and U adhesive systems (10R, 20R, 60R, 10U, 20U and 60U). The same pattern of damage was maintained as seen in the SEM analysis, however, it worsened with increasing the etching time. The amounts of silicium seen on EDS were: E0: 24.73%

Subject(s)
Animals , Cattle , Acid Etching, Dental/methods , Dental Enamel/drug effects , Dental Porcelain/chemistry , Dentin-Bonding Agents/chemistry , Hydrofluoric Acid/chemistry , Bisphenol A-Glycidyl Methacrylate/chemistry , Materials Testing , Microscopy, Electrochemical, Scanning , Polyethylene Glycols/chemistry , Polymethacrylic Acids/chemistry , Reference Values , Reproducibility of Results , Surface Properties , Tensile Strength , Time Factors
14.
Rev. bras. odontol ; 72(1/2): 92-95, Jan.-Jun. 2015. ilus
Article in Portuguese | LILACS | ID: lil-792066

ABSTRACT

A evolução do projeto dos implantes osseointegráveis é resultado do desenvolvimento de diferentes tipos de estruturas em sua superfície. No entanto, ainda existe a necessidade de estudos para definir o tipo de superfície ideal. Esse trabalho discute métodos de avaliação da superfície de implantes que mostram o potencial de determinadas superfícies para induzir mineralização óssea in vitro, partir do uso de células mesenquimais progenitoras. Foram realizadas análises comparativas entre a topografia de implantes com e sem rugosidades nanométricas e o tipo de interação entre pré-osteoblastos semeados diretamente nesses implantes. Características distintas foram observadas em cada superfície.


Improvements in dental implants structure is the result of development of different types of geometrically intelligent surfaces, provided by the emergence of companies interested in innovation of these materials, however, there is still a need for studies to define the type of ideal surface. This work addresses an unprecedented discussion regarding implant surface evaluation methods, able to show the potential of certain areas to induce bone mineralization in vitro. From the use of mesenchymal progenitor cells, which have the capacity to respond to stimuli surface, comparative tests were performed between the topography implants with and without nano-roughness and the type of functional interaction between pre-osteoblasts seeded directly into these implants. Different characteristics of coating cells and mineralization niches on different surfaces were found.

15.
RFO UPF ; 20(1): 28-33, jan.-abr. 2015. ilus
Article in Portuguese | LILACS-Express | LILACS | ID: lil-758376

ABSTRACT

Objetivo: avaliar rugosidade superficial por meio de perfilometria de contato mecânico bem como a resistência à microdureza Knoop em resinas fotoativadas de forma convencional ou com sistemas de polimerização adicional. Materiais e método: 82 corpos de prova foram distribuídos nos seguintes grupos: SI: Solidex®, Z1D: Z100®, Z35D: Z350®, OD: Opallis®, Z1I: Z100®, Z35I: Z350® e OI: Opallis®. Os incrementos de resina foram fotopolimerizados por 40 segundos cada. O grupo contendo a resina de uso indireto Solidex® (SI) e os grupos Z1I, Z35I e OI contendo resinas de uso direto avaliadas como uso indireto tiveram fotopolimerização por 40 segundos mais 7 minutos adicionais com EDG-LUX. As amostras foram armazenadas em água destilada a 37 °C por 24 horas. Em seguida foi realizado o ensaio de rugosidade e posteriormente o de microdureza superficial. As médias coletadas foram analisadas pelo teste não paramétrico de Kruskal-Wallis e o de comparação múltipla de Dunn. Resultados: a resina indicada para uso direto Z100® obteve os maiores valores de microdureza, independente da presença de fotoativação adicional. Já a resina indicada para uso indireto Solidex, obteve os menores valores de microdureza. Os valores de rugosidade não apresentaram diferenças estatísticas entre os materiais analisados. Conclusão: resinas de uso direto com polimerização adicional podem ser bem utilizadas na forma indireta.

16.
Braz. dent. sci ; 18(4): 76-83, 2015. ilus, tab, graf
Article in English | LILACS | ID: lil-786309

ABSTRACT

This in vitro study aimed to compare the degree of root roughness in human teeth treated after using hand curettes, stainless steel, and diamond ultra sound tips. Material and Methods: The scaling was performed on the root surface of 36 human teeth previously standardized and randomly divided in to three groups (n=12). The roughness degree was measured with the aid of a rugosimeter, before and after thes caling, through readings perpendicular and parallel to the scaling direction. The statistical analysis comprised Wilcoxon and Kruskal-Wallis tests (p<0.05). The qualitative and visual complementation of the results was performedby scanning electronic microscopy. Results: The scaling executed with hand curettes increased root roughness (before - Ra median=0.1583μm;after =0.7783μm; before - Rz median =1.667μm; after=7.350μm). The degree of root roughness also increased when stainless steel ultrasound (before - Ra median= 0.1483 μm;after=0.3933 μm; before- Rz median=1.567 μm;after=4.333 μm) and diamond tips were used(before - Ra median=0.1800 μm; after=2.457μm; before - Rz median=1.850 μm; after=18.58μm). Conclusion: The superficial roughness significantly increased in all groups. The scalingwith diamond tips promoted the greatest rootroughness than hand curettes and ultrasoundtips...


O objetivo deste estudo in vitro foi avaliar e comparar o grau de rugosidade radicular em dentes humanos tratados com curetas manuais, pontas ultrassônicas de aço-inox e pontas diamantadas. Materiais e Métodos: A instrumentação foi realizada sobre a superfície radicular de 36 dentes humanos previamente padronizados e divididos aleatoriamente em três grupos (n = 12). O grau de rugosidade foi mensurado, em rugosímetro, antes a após a instrumentação, através de leituras perpendiculares e paralelas ao sentido da instrumentação. Na análise estatística foram utilizados os Testes de Wilcoxon e Kruskal-Wallis (p < 0,05). Para avaliação qualitativa e complementação visual dos resultados foi realizada microscopia eletrônica de varredura. Resultados: A instrumentação realizada com curetas manuais provocou aumento da rugosidade radicular (mediana de Ra antes= 0,1583 μm/depois = 0,7783 μm; mediana de Rz antes= 1,667 μm/depois = 7,350 μm). O grau de rugosidade radicular também aumentou quando se utilizou ponta sultrassônicas de aço-inox (mediana de Ra antes= 0.1483μm/depois = 0,3933 μm; mediana de Rz antes = 1,567μm/depois = 4,333 μm) e pontas diamantadas (mediana de Ra antes = 0,1800 μm/depois = 2,457 μm; mediana de Rz antes = 1,850 μm/depois = 18,58 μm). Conclusão:Houve aumento significativo da rugosidade superficial em todos os grupos. A instrumentação realizada com pontas diamantadas provocou maior aumento da rugosidade radicular quando comparada com o uso de curetas manuais e pontas ultrassônicas...


Subject(s)
Humans , Dental Plaque , Dental Scaling , Periodontics
17.
Braz. dent. sci ; 18(1): 102-110, 2015. ilus, tab
Article in English | LILACS | ID: lil-759968

ABSTRACT

Avaliar a efetividade de diferentes métodos de polimento de superfície de resina composta após a remoção de bráquetes ortodônticos. Material e Métodos: 160 discos de resina composta foram confeccionados a partir de uma matriz de resina acrílica e divididos em 4 grupos, de acordo com o tipo de resina composta usada: G1- microparticulada (n = 40), G2- microhíbrida (n = 40), G3 nanohíbrida (n = 40), G4- nanoparticulada (n = 40). Metade das amostras foi submetida à termociclagem, com 2000 ciclos entre 5 ± 2 °C to 55 ± 2 °C, por um min cada. Metade de cada grupo o bráquete metálico Gemini™ (3MUnitek) e a outra metade o bráquete cerâmico Transcend™ (3M Unitek). A remoção dos bráquetes foi realizada em máquina de teste Universal (EMIC DL model 2000). Metade dos espécimes de cada subgrupo foi polido com pontas diamantadas e a outra metade com discos Sof-Lex. A média da rugosidade superficial dos discos de resina composta foi calculada usando-se um perfilômetro, antes da colagem dos bráquetes, após a remoção dos bráquetes, após a remoção dos excessos de resina e após o polimento. Resultados: O teste ANOVA mostrou que após a remoção dos bráquetes e após o polimento, a rugosidade superficial foi maior no grupo G2 (p < 0,05). Após a remoção dos bráquetes cerâmicos os grupos mostraram maior rugosidade superficial (p < 0,05). Não houve diferença estatisticamente significante na rugosidade entre os grupos termociclados e os tipos de polimento. Conclusão: A qualidade do polimento está sujeita ao tipo de resina utilizada. Os bráquetes cerâmicos induzem a uma maior rugosidade superficial após a remoção. Ambos tipos de polimentos usados foram efetivos...


To evaluate the effectiveness of different methods of composite resin polishing after the removal of orthodontic brackets. Material and Methods: 160 resin discs made from a matrix of acrylic resin were divided into 4 groups, according to the type of composite resin used: G1 - microfilled (n = 40), G2 - microhybrid (n = 40), G3 - nanohybrid (n = 40) and G4 - nanofilled (n = 40). One half of the samples was subjected to thermocycling, at 2000 cycles from 5 ± 2 ºC to 55 ± 2 ºC, for 1 min each. Half of each group of resins was bonded with Gemini™ metallic brackets (3M Unitek) and the other half with Transcend™ ceramic brackets (3M Unitek). The brackets were transferred to a universal testing machine (EMIC DL model 2000). Half of the specimens from each subgroup were polished with diamond burs and the other half with Sof-Lex discs. The average surface roughness of composite resin discs was measured, using a profilometer, before the bonding of brackets, after the removal of brackets, after removing the excess resin and after polishing. Results: After removal of brackets and after polishing, the surface roughness was greater in the microhybrid group (ANOVA, p < 0.05). After removal of ceramic brackets, the groups showed higher surface roughness (ANOVA, p < 0.05). There was no significant difference in roughness related to thermocycling and the type of polishing. Conclusion: The quality of the polish is subjected to the type of resin used. Ceramic brackets provided rougher surfaces after removal. Both types of polishing used are effective...


Subject(s)
Humans , Composite Resins , Dental Polishing
18.
Biosci. j. (Online) ; 30(6): 1959-1966, nov./dec. 2014. tab, ilus
Article in English | LILACS | ID: biblio-948734

ABSTRACT

This in vitro study evaluated the influence of 4 surface sealers on the surface roughness of composite resins. Fifty specimens were divided into 10 groups, as follows: G1. (Control 1) Concept resin; G2. Concept + Fortify; G3. Concept + Biscover; G4. Concept + Lasting Touch; G5. Concept + Fill Glaze; G6. (Control 2) Esthet X; G7. Esthet X + Fortify; G8. Esthet X + Biscover; G9. Esthet X + Lasting Touch; G10. Esthet X + Fill Glaze. Specimens (15mm in length, 4 mm in depth and 5 mm in width) were made using a matrix and were stored in distilled water at 37ºC for 24 hours. After storage, specimens were polished using 320, 600 abrasive SiC paper under running water and the initial roughness was measured using a perfilometer. Surface sealers were applied and a new measurement of roughness was made. Specimens were submitted to 100,000 cycles of abrasive dentifrice brushing followed by another surface roughness measurement. Qualitative analysis was made by using SEM. Results were submitted to 3-way modified ANOVA (p<0.05) and Tukey's test. Results: Surface sealant provided smoother surfaces for both tested composite resins (G2=0.0727, G3=0.0147, G4=0.0307, G5=0.0253, G7=0.0173, G8=0.0333, G9=0.0480, G10=0,0480). After the abrasion test, the control group presented lower roughness surface (G1=0.0600, G6=0.1007). No statistical difference were found between Fortify (G2=0.0740, G7=0.0673) and Biscover (G7=0.0440). Lasting Touch presented rougher surfaces in relation to the other groups (G4= 0.1253, G9=0.0980), followed by Fill Glaze (G5=0.0933, G10= 0.0847). The application of surface sealant did not provide roughness optimization after tooth brushing simulation for the 2 composite resins tested.


Este estudo avaliou, in vitro, a influência de 4 selantes de superfície na rugosidade de duas resinas compostas. Cinqüenta espécimes foram confeccionados e divididos em 10 grupos com 5 espécimes cada, em função da combinação entre resina composta e selante de superfície, sendo: G1. Controle Concept; G2. Concept + Fortify; G3. Concept + Biscover; G4. Concept + Lasting Touch; G5. Concept + Fill Glaze; G6. Controle Esthet X; G7. Esthet X + Fortify; G8. Esthet X + Biscover; G9. Esthet X + Lasting Touch; G10. Esthet X + Fill Glaze. Os espécimes (15mm X 4 mm X 5 mm) foram confeccionados e armazenados em água destilada à 37ºC por 24 horas. Após este período, os espécimes foram planificados com lixas de granulometria 320, 600 e a rugosidade inicial foi aferida. Aplicaram-se os selantes de superfície e uma nova aferição da rugosidade superficial foi realizada. Os espécimes foram submetidos a 100.000 ciclos de escovação, seguido de nova mensuração da rugosidade. Os resultados foram submetidos aos testes ANOVA a 3 critérios e Tukey. A aplicação do selante de superfície diminuiu a rugosidade superficial das resinas compostas testadas (G2=0,0727, G3=0,0147, G4=0,0307, G5=0,0253, G6=0,0960, G7=0,0173, G8=0,0333, G9=0,0480). Nenhuma diferença estatística foi encontrada entre o grupo Fortify (G2=0,0740, G7=0,0673) e Biscover (G7=0,0440). Os maiores valores de rugosidade foram apresentados pelo grupo Lasting Touch (G4= 0,1253, G9=0,0980), seguido do Fill Glaze (G5=0,0933, G10= 0,0847). A aplicação do selante de superfície não otimizou a rugosidade das duas resinas compostas testadas após o teste de abrasão simulada.


Subject(s)
Pit and Fissure Sealants , Composite Resins
19.
RFO UPF ; 19(2): 258-261, maio/agosto 2014.
Article in Portuguese | LILACS-Express | LILACS | ID: lil-737248

ABSTRACT

Introdução: com os avanços tecnológicos, os pesquisa-dores e as indústrias odontológicas tentam desenvolver materiais com características que melhorem a estética e ao mesmo tempo a longevidade clínica. Sabe-se que a superfície de um material restaurador influencia di-retamente na estética e na sua longevidade clínica, in-dicando o sucesso ou insucesso desse. Objetivo: este estudo, realizado por meio da revisão da literatura, teve como objetivo apresentar os achados da literatu-ra sobre a comparação da rugosidade superficial dos compósitos nanoparticulados em relação aos compó-sitos microparticulados e microhibridos, para verificar os possíveis sucessos e insucessos dessa tecnologia de ?nanoparticulas? implantada recentemente na odon-tologia. Revisão de literatura: muitos estudos mostram que uma superfície irregular, com rugosidades, impli-ca no manchamento e no acúmulo de biofilme dental, acarretando prejuízo à restauração e à saúde bucal do paciente. Também se conseguiu observar importantes diferenças superficiais dos compósitos nanoparticula-dos com os compósitos microhíbrido e microparticu-lado. Considerações finais: a superfície dos compósitos nanoparticulados é mais regular que a dos compósitos microparticulados e microhíbridos, essa regularidade é fundamental para a estética e para a longevidade clíni-ca do material.

20.
Ortho Sci., Orthod. sci. pract ; 7(25): 43-50, 2014. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-729347

ABSTRACT

Na descolagem de bráquetes ortodônticos pode ocorrer a perda de esmalte na interface adesivo-esmalte. O objetivo deste estudo foi avaliar os possíveis danos à superfície do esmalte com recolagens de bráquetes metálicos e cerâmicos novos por meio da resistência adesiva ao cisalhamento (RAC), da análise do índice de adesivo remanescente (IAR), da avaliação da rugosidade de superfície (RA) e pela análise de microscopia eletrônica (MEV). Foram usados 120 pré-molares, divididos aleatoriamente em 4 grupos de 30 dentes: CS (Controle Saliva); CA (Condicionamento Ácido); M (Metálico) e C (Cerâmico). Foram colados 120 bráquetes metálicos e 120 cerâmicos, para os grupos M e C, em quatro tempos. Os ensaios mecânicos foram realizados em máquina SHIMADZU, na velocidade 0,5 mm/min. Na avaliação da RAC, o ANOVA a dois critérios demonstrou não haver diferenças (p= 0,052) entre os grupos. Na avaliação do IAR, o teste U de Mann-Whitney demonstrou diferença entre os grupos (p< 0,001), onde o grupo cerâmico exibiu escores mais altos que o metálico. Para a rugosidade, o ANOVA a um critério demonstrou que o grupo M apresentou maior RA (p< 0,001). O teste de Tukey demonstrou que os grupos M e C, após o polimento com discos Sof-Lex, exibiram valores de rugosidade inferiores aos demais grupos. Conclui-se que na remoção de bráquetes metálicos ou cerâmicos e da resina remanescente existe maior risco de danos ao esmalte nas recolagens sucessivas. O polimento com discos Sof-Lex promoveu superfície com maior lisura do esmalte.


Debonding of orthodontic brackets may cause enamel surface loss primarily at the adhesive-enamel interface. The purpose of the present study was to evaluate by means of shear bond strength (SBS), adhesive remnant index (ARI), assessment of surface roughness and electron microscope analysis, the possible damages at enamel surface with repeated rebonding of new metallic and ceramic brackets. One hundred and twenty human premolars were randomly divided into 4 groups of 30 premolars each: CS (Saliva Control); CA (Acid Etching); M (Metal); C (Ceramic). For CA group, 4 repeated acid conditionings were performed. One hundred and twenty metallic and ceramic brackets, for groups M and C, were bonded and rebonded respectively at 4 stages. Mechanical trials were obtained with a SHIMADZU testing machine at 0.5 mm/min cross-speed. The SBS results were statistically tested with ANOVA, and no statistically significant differences (p=0.052) were observed. The ARI was evaluated by Mann-Whitney test, which demonstrated that there was a statistically significant difference between metallic and ceramic brackets (p<0.001). The ceramic group exhibited higher statistically significant scores for ARI than the metallic group. The roughness assessment was made with one-way ANOVA, that showed statistically significant differences between groups (p<0.001). Tukey´s test has demonstrated that the M and C groups that were polished with SofLex discs had statistically significant lower roughness values as compared to other groups. Polishing with Sof-lex discs, lead to increased smoothness of enamel surfaces.


Subject(s)
Humans , Adolescent , Dental Enamel , Orthodontic Brackets
SELECTION OF CITATIONS
SEARCH DETAIL